TP-210 Infant Phototherapy Unit
Standard Compostion:
¡ñ Single-side & LED lights; ¡ñ LED Digital Timer, display therapy time & total time; ¡ñ Top-put type applicable for any model of incubator.
Technical Specification:
POWER Model TP-200-1E......................................................................................110 / 120 Vac, 50Hz / 60Hz Model TP-200-2E.......................................................................................220 / 240Vac, 50Hz / 60Hz Input power............................................................................................................................ ¡Ü50VA Accord with IEC 60601-1 standard, this device is in class I, continuous handling. Irradiance phototherapy distance..................................................................................35cm¡«37cm Effective area..................................................................................................................45cm¡Á24cm Ebi in effective area surface...........................................................................................500¦ÌW/cm2 Ebi max in effective area surface......................................................................................650¦ÌW/cm2 Ebi average in effective area surface...............................................................................500¦ÌW/cm2 Uniformity of Ebi..................................................................................................................................>0.4¡¡Infrared radiation in effective area...................................................<1mW/cm2(760nm<¦Ë¡Ü1400nm= Ultraviolet radiation in effective area.....................................<1.0¡Á10-5mW/cm2 (180nm<¦Ë¡Ü400nm= Time display accuracy...........................................................................................................2h¡À1min Operate noise.............................................................¡Ü50dB(A)£¨ambit noise is lower than 40dB(A)£© ENVIRONMENT CONDITION Environment temperature Operate temperature range........................................................................................ +10¡æ ¡« +30¡æ Storage temperature range...................................................................................... -40¡æ ¡« +70¡æ Environment humidity Operate humidity range.................................................................................................... 30%¡«75% Storage humidity range............................................................................................................ ¡Ü80% Transport and storage atmospheric pressure range.......................................... 500hPa¡«1060hPa |