Chinese | English
HOME ABOUT US PRODUCTS FEEDBACK SERVICE CONTACT US
Laboratory Equipment
Microplate Reader
Microplate Washer
Hematology Analyzer
Chemistry Analyzer
Spectrophotometer
lmmunoassay Analyzer

Hospital Equipment
ECG
Ventilator
Monitor
Ultrasound Scanner
X-ray Machine
Film Processor
Infant Incubator
Radiant Warmer
Phototherapy Unit
Dental Unit

Products
TW-1100 Infant Radiant Warmer
Standard Composition
Servo Control Mode:air temperature
Instant Parameter Display: set temp, skin temp, heat power rate;
Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
Tilting Bed with Rotary Radiant Head
X-ray Cassette Tray under infant bed, examination light of high illuminance;
Use anti-blast quartz infrared tube as radiant heating source.
Technical Specification:
This equipment belongs to Class, Type BF, continuous operation common equipment.
POWER
Model TW-1000-1E.............................................................................AC 110 / 120 V, 50Hz / 60Hz
Model TW-1000-2E........................................................................... AC 220 / 240V, 50Hz / 60Hz
Input Power..................................................................................................................... 1000VA
TEMPERATURE CONTROL RANGE AND RELATIVE SPECIFICATION
Control mode........................................................................................................................baby mode
Temperature control range....................................................................................................25桫37.
Skin temperature sensor measure range..............................................................................20桫42
Deviation between sensor measure temperature and control temperature...................................0.5
Skin Sensor Precision.............................................................................................................. 0.3
Bed surface temperature Uniformity................................................................................................ 1
Temperature Rise Time ............................................................................................................. 45min
Bed tiltable.........................................................................................continues adjustable in 10
ALARM
Sensor failure alarm.....................................................alarm with audible and visual when sensor open                                                                                       circuit, short circuit or disconnect, cut off power.
Over temperature alarm.................................................alarm with audible and visual when displayed                                                                                                                         temperature was approach 38.
Deviation alarm......................................after temperature equilibrium, alarm with audible and visual                                                                                          when displayed temperature was 1 above or below control temperature, cut off power if above 1.                                                       
Power failure alarm................................................... alarm with audible and visual when power failure
ENVIRONMENT TEMPERATURE
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range.............................................................................................18桫30
Store temperature range...........................................................................................  -20桫+55
ENVIRONMENT HUMIDITY
Operate humidity range........................................................................................ 30%RH75%RH
Store humidity range......................................................................................................... 93%RH
ATMOSPHERIC PRESSURE
Transport and Store atmospheric pressure range................................................500hPa1060hPa
Operate atmospheric pressure range...................................................................700hPa1060hPa
STREAM VELOCITY
Ambit environment stream velocity................................................................................... 0.3m/s

Tel: 0086-25-58651928   Fax:0086-25-83254278 Email: teriomed@gmail.com , info@teriomed.com