Chinese | English
HOME ABOUT US PRODUCTS FEEDBACK SERVICE CONTACT US
Laboratory Equipment
Microplate Reader
Microplate Washer
Hematology Analyzer
Chemistry Analyzer
Spectrophotometer

Hospital Equipment
ECG
Ventilator
Monitor
Ultrasound Scanner
X-ray Machine
Film Processor
Infant Incubator
Radiant Warmer
Phototherapy Unit
Dental Unit
Hospital Furniture

Veterinary Products
Autoclave
Ultrasound Scanner
Surgical Light
Defibrillator

Products
TV-400 Portable Ventilator 
 
Features:
Used for pediatric and adult patients.
Used for first aid, ambulance and patients transport within hospital.
Physical Specifications:
Ventilator Dimensions:
Width:300mm  Depth:140mm  Height:230mm   Weight: 3Kg;
Carrying packages Dimensions:
Width:460mm  Depth:160mm  Height:350mm   Weight:7Kg;
Packaging Dimensions:
Width:620mm  Depth:410mm  Height:240mm   Weight:11Kg.
Electrical Specifications:
Input Voltage Requirements:
No.1£ºAC100~240V, 50/60HZ;
No.2:  DC : 12V  1.5A;
No.3: Internal Li-battery DC12V 2200mA.
Pneumatic Specifications:
Oxygen Inlet:
NO.1: Pressurized Oxygen  0.45 MPa¡À10% medical oxygen. (Availability through Oxygen Pressure Reducer provided as a accessory)
NO.2: 2L  Aluminum Alloy Oxygen Cylinder 
Performance Specification And Tolerances:
Controls and sets                                   
Ventilator  Parameters
Ranges
Power
 
Modes:CMV(IPPV), A/C(SIPPV), SIMV, SPONT, SIGH, PEEP(Choice for suppliers)
Tidal Volume
50~1200ml
Breath Rate
5~60 bpm £¨1~12 bpm for SIMV£©
Sigh
1~10 per 100 breath
%O2
45~100%
Trigger Level
-10~0hpa
PIP
0~60hpa
Base Flow
0~5L/min
Peep
0~10 hpa
Over Pressure Relief
< 60hpa
Performance Specification:
Alarms and Indicators                                         
Ventilator  Parameters
Ranges
High Pressure Alarm Limit
20~60hpa to be set
flash, red indicator
Low Pressure Alarm Limit
2~20hpa to be set
Red indicator
Low Battery Voltage
Surplus energy can work for an hour
red indicator
Alarm
Red indicator
Alarm Silence
Yellow indicator
Power
Green indicator
Charging Indicator
Green indicator
Performance Specification:
Monitors                                                    
Ventilator Parameters
Ranges
Main Circuit Pressure 
-20~100hPa
Wave Display                                                
Main Circuit Pressure
What Is Provided:
Parts Name
Number
Specification
Ventilator
1
 
Oxygen Cylinder
1
2.0L can be used for 1 hour
Carry bag
1
With cylinder
Breath Circuit
1
1.2m
Breath Value
1
 
Mask
1
 
Chargers
1
 
Li-Battery
1
Can be used for 8 hours
Wrench Tool
1
 
Oxygen Pressure Reducer
1
For Normal Oxygen Cylinder
Oxygen Bridge
1
 
Hand Book
1
 
CD For Operation
1
 
 

Tel: 0086-25-58651928   Fax:0086-25-83254278 Email: teriomed@gmail.com
© 2007-2008 teriomed.com all rights reserved. support:Rurui.net