TW-2100B Infant Radiant Warmer
Standard Composition
¡ñTemperature Control Mode: pre-heating control, servo control & manual control; ¡ñ Instant Parameter Display: set temp, skin temp, heat power rate; ¡ñ Built-in APGAR Timer and >37¡æ preset function ¡ñ Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override; ¡ñ Tilting Bed with Rotary Radiant Head; ¡ñ X-ray Cassette Tray under infant bed, examination light of high illuminance; ¡ñ Use anti-blast quartz infrared tube as radiant heating source; ¡ñ With phototherapy unit; ¡ñ With two oxygen cylinders; ¡ñ With Suction, with neonate resuscitation.
Technical Specification:
This equipment belongs to Class¢ñ, Type BF, continuous operation common equipment.
POWER Model TW-2000B-1E....................................................................................AC 110 / 120 V, 50Hz / 60Hz Model TW-2000B-2E................................................................................. AC 220 / 240V, 50Hz / 60Hz Input Power......................................................................................................................... ¡Ü1000VA
TEMPERATURE CONTROL RANGE AND RELATIVE SPECIFICATION Control mode..................................................................Pre-warm mode, manual mode, baby mode Temperature control range.................................................. 25¡æ¡«37¡æ,for set temperature ¡Ü37¡æ, 37¡æ¡«38¡æ,for set temperature >37¡æ
Skin temperature sensor measure range.......................................................................20¡æ¡«42¡æ Deviation between sensor measure temperature and control temperature...........................¡Ü0.5¡æ Skin Sensor Precision........................................................................................................... ¡Ü0.3¡æ Bed surface temperature Uniformity........................................................................................ ¡Ü1¡æ Temperature Rise Time ..................................................................................................... ¡Ü45min Bed tiltable...........................................................................................continues adjustable in ¡À10¡ã
ALARM Sensor failure alarm................................................alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power. Over temperature alarm.....................alarm with audible and visual when displayed temperature was approach 38¡æ for set temperature ¡Ü37¡æ, or approach 39¡æ for set temperature >37¡æ, cut off power. Deviation alarm.................................after temperature equilibrium, alarm with audible and visual when displayed temperature was 1¡æ above or below control temperature, cut off power if above 1¡æ Power failure alarm.................................................. alarm with audible and visual when power failure APGAR time...................................................... alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes. ENVIRONMENT TEMPERATURE (It is a suggestion that please do not use outside of the allow environment.) Operate temperature range............................................................................................18¡æ¡«30¡æ Store temperature range.......................................................................................... -20¡æ¡«+55¡æ ENVIRONMENT HUMIDITY Operate humidity range......................................................................................... 30%RH¡«75%RH Store humidity range........................................................................................................... ¡Ü93%RH ATMOSPHERIC PRESSURE Transport and Store atmospheric pressure range.................................................500hPa¡«1060hPa Operate atmospheric pressure range....................................................................700hPa¡«1060hPa
STREAM VELOCITY Ambit environment stream velocity..................................................................................... ¡Ü0.3m/s
Optional Part
XYQ1003 Inter low-pressure suction.
TD1001 Phototherapy lights. Mounting beside radiant head of infant radiant warmer.
Specifications |
TW-1000 |
YW-2000 |
TW-2000(B) |
|
Operational condition: |
|
|
Environment temperature |
+18¡æ¡«+30¡æ |
+18¡æ¡«+30¡æ |
+18¡æ¡«+30¡æ |
|
Environment relative humidity |
30%¡«75% |
30%¡«75% |
30%¡«75% |
|
Environment air velocity of flow |
|
<0.3m/s |
<0.3m/s |
<0.3m/s |
Power requirement |
¡Ü1000VA |
¡Ü1000VA |
¡Ü1000VA |
Temperature control mode |
Auto |
Pre-heat¡¢auto and manual |
Pre-heat¡¢auto and manual |
TemperatureControl Range |
25¡æ¡«37¡æ |
25¡æ¡«37¡æ |
25¡æ¡«37¡æ |
Temperature override mode to |
----- |
38¡æ |
38¡æ |
Temperature sensor accuracy |
¡Ü0.3¡æ |
¡Ü0.3¡æ |
¡Ü0.3¡æ |
Mattress temperature uniformity |
¡Ü2.0¡æ |
¡Ü2.0¡æ |
¡Ü2.0¡æ |
Temperature rise time |
¡Ü45 min |
¡Ü45 min |
¡Ü45 min |
Heat output indicate |
0~100% |
0~100% |
0~100% |
Radiant box horizon angle adjust range |
0~¡À90¡ãstep-less |
0~¡À90¡ã step-less |
0~¡À90¡ã step-less |
Mattress Tray Size |
68cm¡Á56cm |
68cm¡Á56cm |
68cm¡Á56cm |
Mattress tilt adjust range |
0~¡À10¡ã step-less |
0~¡À10¡ã step-less |
0~¡À10¡ã step-less |
Mattress tray Max. load |
10 kg |
10 kg |
10 kg |
Transfusion pole Max. load |
2 kg |
2 kg |
2 kg |
Shelf Max. load |
2 kg |
2 kg |
2 kg |
X-ray |
Yes |
Yes |
Yes |
RS-232 Connector |
---- |
Yes |
Yes |
Mattress to Radiant box |
81 cm |
81 cm |
81 cm |
Heater infrared wavelength |
1¡«3 ¦Ìm |
1¡«3 ¦Ìm |
1¡«3 ¦Ìm |
APGAR Timer |
----- |
Yes |
Yes |
Alarms |
|
Power failure alarm |
Yes |
Yes |
Yes |
Sensor failure alarm |
Yes |
Yes |
Yes |
Temperature deviation alarm |
¡À1.0¡æ |
¡À1.0¡æ |
¡À1.0¡æ |
Over temperature alarm |
¡Ü38.0¡æ |
¡Ü38.0¡æ¡¢¡Ü39.0¡æ |
¡Ü38.0¡æ¡¢¡Ü39.0¡æ |
System failure alarm |
----- |
Yes |
Yes |
Low-pressure suction |
------ |
----- |
Yes |
Pressure adjust range |
------ |
---- |
0¡«22Kp(0¡«165mmHg) |
Operating noise |
------ |
---- |
¡Ü55dB |
White Phototherapy light |
------ |
------ |
1 set |
7LOxygen cylinder (with oxygen manometer & oxygen flow meter£© |
------ |
------ |
2 sets |
Neonate resuscitation bag |
------ |
------ |
1 set |
Packing size |
110¡Á90¡Á110 cm |
110 ¡Á90¡Á110 cm |
110 ¡Á90¡Á110 cm |
Net weight |
85 kg |
85 kg |
95 kg |
Gross Weight |
115 kg |
115 kg |
125 kg | |