TW-2100B Infant Radiant Warmer
Standard Composition
¡ñTemperature Control Mode: pre-heating control, servo control & manual control;
¡ñ Instant Parameter Display: set temp, skin temp, heat power rate;
¡ñ Built-in APGAR Timer and >37¡æ preset function
¡ñ Audible/Visual Alarms: temp deviation, sensor failure, power failure, temp override;
¡ñ Tilting Bed with Rotary Radiant Head;
¡ñ X-ray Cassette Tray under infant bed, examination light of high illuminance;
¡ñ Use anti-blast quartz infrared tube as radiant heating source;
¡ñ With phototherapy unit;
¡ñ With two oxygen cylinders;
¡ñ With Suction, with neonate resuscitation.
Technical Specification:
This equipment belongs to Class¢ñ, Type BF, continuous operation common equipment.
POWER
Model TW-2000B-1E....................................................................................AC 110 / 120 V, 50Hz / 60Hz
Model TW-2000B-2E................................................................................. AC 220 / 240V, 50Hz / 60Hz
Input Power......................................................................................................................... ¡Ü1000VA
TEMPERATURE CONTROL RANGE AND RELATIVE SPECIFICATION
Control mode..................................................................Pre-warm mode, manual mode, baby mode
Temperature control range.................................................. 25¡æ¡«37¡æ,for set temperature ¡Ü37¡æ,                                37¡æ¡«38¡æ,for set temperature >37¡æ                                                                                                                      
Skin temperature sensor measure range.......................................................................20¡æ¡«42¡æ
Deviation between sensor measure temperature and control temperature...........................¡Ü0.5¡æ
Skin Sensor Precision........................................................................................................... ¡Ü0.3¡æ
Bed surface temperature Uniformity........................................................................................ ¡Ü1¡æ
Temperature Rise Time ..................................................................................................... ¡Ü45min
Bed tiltable...........................................................................................continues adjustable in ¡À10¡ã
ALARM
Sensor failure alarm................................................alarm with audible and visual when sensor open
circuit, short circuit or disconnect, cut off power.
Over temperature alarm.....................alarm with audible and visual when displayed temperature was                                                                             approach 38¡æ for set temperature ¡Ü37¡æ, or approach 39¡æ for set temperature >37¡æ, cut off power.
Deviation alarm.................................after temperature equilibrium, alarm with audible and  visual when                                                                                         displayed temperature was 1¡æ above or below control temperature, cut off power if above 1¡æ                                                                             Power failure alarm.................................................. alarm with audible and visual when power failure
APGAR time...................................................... alarm with audible when run between 50 seconds to                                                                                                           1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes.
ENVIRONMENT TEMPERATURE
(It is a suggestion that please do not use outside of the allow environment.)
Operate temperature range............................................................................................18¡æ¡«30¡æ
Store temperature range..........................................................................................  -20¡æ¡«+55¡æ
ENVIRONMENT HUMIDITY
Operate humidity range......................................................................................... 30%RH¡«75%RH
Store humidity range........................................................................................................... ¡Ü93%RH
ATMOSPHERIC PRESSURE
Transport and Store atmospheric pressure range.................................................500hPa¡«1060hPa
Operate atmospheric pressure range....................................................................700hPa¡«1060hPa
STREAM VELOCITY
Ambit environment stream velocity..................................................................................... ¡Ü0.3m/s
Optional Part         
XYQ1003 Inter low-pressure suction. 
 
 
                                                    
TD1001 Phototherapy lights. Mounting beside radiant head of infant radiant warmer.
 
 
 
 
Specifications
TW-1000
YW-2000
TW-2000(B)
 
Operational condition:
 
 
Environment temperature
+18¡æ¡«+30¡æ
+18¡æ¡«+30¡æ
+18¡æ¡«+30¡æ
 
Environment relative humidity
30%¡«75%
30%¡«75%
30%¡«75%
 
Environment air velocity of flow
 
<0.3m/s
<0.3m/s
<0.3m/s
Power requirement
¡Ü1000VA
¡Ü1000VA
¡Ü1000VA
Temperature control mode
Auto
Pre-heat¡¢auto and manual
Pre-heat¡¢auto and manual
TemperatureControl Range
25¡æ¡«37¡æ
25¡æ¡«37¡æ
25¡æ¡«37¡æ
Temperature override mode to
-----
38¡æ
38¡æ
Temperature sensor accuracy
¡Ü0.3¡æ
¡Ü0.3¡æ
¡Ü0.3¡æ
Mattress temperature uniformity
¡Ü2.0¡æ
¡Ü2.0¡æ
¡Ü2.0¡æ
Temperature rise time
¡Ü45 min
¡Ü45 min
¡Ü45 min
Heat output indicate
0~100%
0~100%
0~100%
Radiant box horizon angle adjust range
0~¡À90¡ãstep-less
0~¡À90¡ã step-less
0~¡À90¡ã step-less
Mattress Tray Size
68cm¡Á56cm
68cm¡Á56cm
68cm¡Á56cm
Mattress tilt adjust range
0~¡À10¡ã step-less
0~¡À10¡ã step-less
0~¡À10¡ã step-less
Mattress tray Max. load
10 kg
10 kg
10 kg
Transfusion pole Max. load
2 kg
2 kg
2 kg
Shelf Max. load
2 kg
2 kg
2 kg
X-ray
Yes
Yes
Yes
RS-232 Connector
----
Yes
Yes
Mattress to Radiant box
81 cm
81 cm
81 cm
Heater infrared wavelength
1¡«3 ¦Ìm
1¡«3 ¦Ìm
1¡«3 ¦Ìm
APGAR Timer
-----
Yes
Yes
Alarms
 
Power failure alarm
Yes
Yes
Yes
Sensor failure alarm
Yes
Yes
Yes
Temperature deviation alarm
¡À1.0¡æ
¡À1.0¡æ
¡À1.0¡æ
Over temperature alarm
¡Ü38.0¡æ
¡Ü38.0¡æ¡¢¡Ü39.0¡æ
¡Ü38.0¡æ¡¢¡Ü39.0¡æ
System failure alarm
-----
Yes
Yes
Low-pressure suction
------
-----
Yes
Pressure adjust range
------
----
0¡«22Kp(0¡«165mmHg)
Operating noise
------
----
¡Ü55dB
White Phototherapy light
------
------
1 set
7LOxygen cylinder (with oxygen manometer & oxygen flow meter£©
------
------
2 sets
Neonate resuscitation bag
------
------
1 set
Packing size
110¡Á90¡Á110 cm
110 ¡Á90¡Á110 cm
110 ¡Á90¡Á110 cm
Net weight
85 kg
85 kg
95 kg
Gross Weight
115 kg
115 kg
125 kg